False negative rate of COVID-19 PCR testing: a discordant testing analysis.


ABSTRACT:

Background

COVID-19 is diagnosed via detection of SARS-CoV-2 RNA using real time reverse-transcriptase polymerase chain reaction (rtRT-PCR). Performance of many SARS-CoV-2 rtRT-PCR assays is not entirely known due to the lack of a gold standard. We sought to evaluate the false negative rate (FNR) and sensitivity of our laboratory-developed SARS-CoV-2 rtRT-PCR targeting the envelope (E) and RNA-dependent RNA-polymerase (RdRp) genes.

Methods

SARS-CoV-2 rtRT-PCR results at the Public Health Laboratory (Alberta, Canada) from January 21 to April 18, 2020 were reviewed to identify patients with an initial negative rtRT-PCR followed by a positive result on repeat testing within 14 days (defined as discordant results). Negative samples from these discordant specimens were re-tested using three alternate rtRT-PCR assays (targeting the E gene and N1/N2 regions of the nucleocapsid genes) to assess for false negative (FN) results.

Results

During the time period specified, 95,919 patients (100,001 samples) were tested for SARS-CoV-2. Of these, 49 patients were found to have discordant results including 49 positive and 52 negative swabs. Repeat testing of 52 negative swabs found five FNs (from five separate patients). Assuming 100% specificity of the diagnostic assay, the FNR and sensitivity in this group of patients with discordant testing was 9.3% (95% CI 1.5-17.0%) and 90.7% (95% CI 82.6-98.9%) respectively.

Conclusions

Studies to understand the FNR of routinely used assays are important to confirm adequate clinical performance. In this study, most FN results were due to low amounts of SARS-CoV-2 virus concentrations in patients with multiple specimens collected during different stages of infection. Post-test clinical evaluation of each patient is advised to ensure that rtRT-PCR results are not the only factor in excluding COVID-19.

SUBMITTER: Kanji JN 

PROVIDER: S-EPMC7794619 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC8170512 | biostudies-literature
| S-EPMC8080800 | biostudies-literature
| S-EPMC7151360 | biostudies-literature
| S-EPMC7849051 | biostudies-literature
| S-EPMC7728293 | biostudies-literature
| S-EPMC8064808 | biostudies-literature
| S-EPMC7294962 | biostudies-literature
| S-EPMC7262304 | biostudies-literature
| S-EPMC8841043 | biostudies-literature
| S-EPMC7536520 | biostudies-literature