Unknown

Dataset Information

0

Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.


ABSTRACT: Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to-background ratio (the VMSBR model). The purpose of this work was to apply the VMSBR model and six other segmentation algorithms to a sample of lung tumors. PET and 4D CT were performed in the same imaging session for 23 patients (24 tumors) for radiation therapy planning. Internal target volumes (ITVs) were autosegmented on maximum intensity projection (MIP) of cine CT. ITVs were delineated on PET using the following methods: 15%, 35%, and 42% of maximum activity concentration, standardized uptake value (SUV) of 2.5 g/mL, 15% of mean activity concentration plus background, a linear function of mean SUV, and the VMSBR model. Predicted threshold values from each method were compared to measured optimal threshold values, and resulting volume magnitudes were compared to cine-CT-derived ITV. Correlation between predicted and measured threshold values ranged from slopes of 0.29 for the simplest single-threshold techniques to 0.90 for the VMSBR technique. R2 values ranged from 0.07 for the simplest single-threshold techniques to 0.86 for the VMSBR technique. The VMSBR segmentation technique that included volume, motion, and source-to-background ratio, produced accurate ITVs in patients when compared with cine-CT-derived ITV.

SUBMITTER: Riegel AC 

PROVIDER: S-EPMC5711243 | biostudies-other | 2014 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.

Riegel Adam C AC   Bucci M Kara MK   Mawlawi Osama R OR   Ahmad Moiz M   Luo Dershan D   Chandler Adam A   Pan Tinsu T  

Journal of applied clinical medical physics 20140106 1


Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to-background ratio (the VMSBR model). The purpose of this work was to apply the VMSBR model and six other segmentation algorithms to a sample of lung tumors. PET and 4D CT were perfo  ...[more]

Similar Datasets

2015-02-09 | E-MTAB-3175 | biostudies-arrayexpress
2011-11-01 | GSE21217 | GEO
| S-EPMC6923299 | biostudies-literature
| S-EPMC5607632 | biostudies-literature
| S-EPMC7807641 | biostudies-literature
| 2456821 | ecrin-mdr-crc
2011-11-01 | E-GEOD-21217 | biostudies-arrayexpress
| S-EPMC5525742 | biostudies-literature
2020-03-18 | GSE131769 | GEO
| S-EPMC6334209 | biostudies-literature