A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics


ABSTRACT: To further integrate mass spectrometry (MS)-based proteomics into biomedical research and especially into clinical settings, high throughput and robustness are essential requirements. They are largely met in high-flow rate chromatographic systems for small molecules but these are not sufficiently sensitive for proteomics applications. Here we describe a new concept that delivers on these requirements while maintaining the sensitivity of current nano-flow LC systems. Low-pressure pumps elute the sample from a disposable trap column, simultaneously forming a chromatographic gradient that is stored in a long storage loop. An auxiliary gradient creates an offset, ensuring the re-focusing of the peptides before the separation on the analytical column by a single high-pressure pump. This simplified design enables robust operation over thousands of sample injections. Furthermore, the steps between injections are performed in parallel, reducing overhead time to a few minutes and allowing analysis of more than 200 samples per day. From fractionated HeLa cell lysates, deep proteomes covering more than 130,000 sequence unique peptides and close to 10,000 proteins were rapidly acquired. Using this data as a library, we demonstrate quantitation of 5200 proteins in only 21 min. Thus, the new system - termed Evosep One - analyzes samples in an extremely robust and high throughput manner, without sacrificing in depth proteomics coverage.

INSTRUMENT(S): Q Exactive

ORGANISM(S): Homo Sapiens (human)

SUBMITTER: Mario Oroshi  

LAB HEAD: Matthias Mann

PROVIDER: PXD010393 | Pride | 2018-08-16

REPOSITORIES: Pride

altmetric image

Publications

A Novel LC System Embeds Analytes in Pre-formed Gradients for Rapid, Ultra-robust Proteomics.

Bache Nicolai N   Geyer Philipp E PE   Bekker-Jensen Dorte B DB   Hoerning Ole O   Falkenby Lasse L   Treit Peter V PV   Doll Sophia S   Paron Igor I   Müller Johannes B JB   Meier Florian F   Olsen Jesper V JV   Vorm Ole O   Mann Matthias M  

Molecular & cellular proteomics : MCP 20180813 11


To further integrate mass spectrometry (MS)-based proteomics into biomedical research and especially into clinical settings, high throughput and robustness are essential requirements. They are largely met in high-flow rate chromatographic systems for small molecules but these are not sufficiently sensitive for proteomics applications. Here we describe a new concept that delivers on these requirements while maintaining the sensitivity of current nano-flow LC systems. Low-pressure pumps elute the  ...[more]

Similar Datasets

2020-06-09 | PXD018874 | Pride
2023-05-09 | PXD039414 | Pride
2022-12-01 | PXD036786 | Pride
2019-12-09 | PXD015087 | Pride
2021-08-12 | PXD021285 | Pride
2019-07-29 | PXD013330 | Pride
2020-01-14 | PXD012703 | Pride
2018-09-19 | PXD008978 | Pride
2018-06-20 | E-MTAB-6063 | biostudies-arrayexpress
2017-12-11 | PXD008094 | Pride