Unknown

Dataset Information

0

A Facile Electrochemical Preparation of Reduced Graphene Oxide@Polydopamine Composite: A Novel Electrochemical Sensing Platform for Amperometric Detection of Chlorpromazine.


ABSTRACT: We report a novel and sensitive amperometric sensor for chlorpromazine (CPZ) based on reduced graphene oxide (RGO) and polydopamine (PDA) composite modified glassy carbon electrode. The RGO@PDA composite was prepared by electrochemical reduction of graphene oxide (GO) with PDA. The RGO@PDA composite modified electrode shows an excellent electro-oxidation behavior to CPZ when compared with other modified electrodes such as GO, RGO and GO@PDA. Amperometric i-t method was used for the determination of CPZ. Amperometry result shows that the RGO@PDA composite detects CPZ in a linear range from 0.03 to 967.6??M. The sensor exhibits a low detection limit of 0.0018??M with the analytical sensitivity of 3.63?±?0.3??A?M(-1?)cm(-2). The RGO@PDA composite shows its high selectivity towards CPZ in the presence of potentially interfering drugs such as metronidazole, phenobarbital, chlorpheniramine maleate, pyridoxine and riboflavin. In addition, the fabricated RGO@PDA modified electrode showed an appropriate recovery towards CPZ in the pharmaceutical tablets.

SUBMITTER: Palanisamy S 

PROVIDER: S-EPMC5030524 | biostudies-literature | 2016 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Facile Electrochemical Preparation of Reduced Graphene Oxide@Polydopamine Composite: A Novel Electrochemical Sensing Platform for Amperometric Detection of Chlorpromazine.

Palanisamy Selvakumar S   Thirumalraj Balamurugan B   Chen Shen-Ming SM   Wang Yi-Ting YT   Velusamy Vijayalakshmi V   Ramaraj Sayee Kannan SK  

Scientific reports 20160921


We report a novel and sensitive amperometric sensor for chlorpromazine (CPZ) based on reduced graphene oxide (RGO) and polydopamine (PDA) composite modified glassy carbon electrode. The RGO@PDA composite was prepared by electrochemical reduction of graphene oxide (GO) with PDA. The RGO@PDA composite modified electrode shows an excellent electro-oxidation behavior to CPZ when compared with other modified electrodes such as GO, RGO and GO@PDA. Amperometric i-t method was used for the determination  ...[more]

Similar Datasets

| S-EPMC5539141 | biostudies-literature
| S-EPMC8203652 | biostudies-literature
| S-EPMC6289493 | biostudies-literature
| S-EPMC7795248 | biostudies-literature
| S-EPMC6915725 | biostudies-literature
| S-EPMC8153741 | biostudies-literature