Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.


ABSTRACT: BACKGROUND:To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. MATERIALS AND METHODS:A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. RESULTS:The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all of p > 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 ± 0.48 mSv) and C (2.72 ± 0.54 mSv), compared with group A (3.58 ± 0.67 mSv) (p < 0.05). CONCLUSION:CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.

SUBMITTER: Cha MJ 

PROVIDER: S-EPMC7365455 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.

Cha Min Jae MJ   Kim Sung Mok SM   Ahn Tae Ran TR   Choe Yeon Hyeon YH  

PloS one 20200716 7


<h4>Background</h4>To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30.<h4>Materials and methods</h4>A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 40  ...[more]