Homogeneous non-selective and slice-selective parallel-transmit excitations at 7 Tesla with universal pulses: A validation study on two commercial RF coils.


ABSTRACT: Parallel transmission (pTx) technology, despite its great potential to mitigate the transmit field inhomogeneity problem in magnetic resonance imaging at ultra-high field (UHF), suffers from a cumbersome calibration procedure, thereby making the approach problematic for routine use. The purpose of this work is to demonstrate on two different 7T systems respectively equipped with 8-transmit-channel RF coils from two different suppliers (Rapid-Biomed and Nova Medical), the benefit of so-called universal pulses (UP), optimized to produce uniform excitations in the brain in a population of adults and making unnecessary the calibration procedures mentioned above. Non-selective and slice-selective UPs were designed to return homogeneous excitation profiles throughout the brain simultaneously on a group of ten subjects, which then were subsequently tested on ten additional volunteers in magnetization prepared rapid gradient echo (MPRAGE) and multi-slice gradient echo (2D GRE) protocols. The results were additionally compared experimentally with the standard non-pTx circularly-polarized (CP) mode, and in simulation with subject-specific tailored excitations. For both pulse types and both coils, the UP mode returned a better signal and contrast homogeneity than the CP mode. Retrospective analysis of the flip angle (FA) suggests that the FA deviation from the nominal FA on average over a healthy adult population does not exceed 11% with the calibration-free parallel-transmit pulses whereas it goes beyond 25% with the CP mode. As a result the universal pulses designed in this work confirm their relevance in 3D and 2D protocols with commercially available equipment. Plug-and-play pTx implementations henceforth become accessible to exploit with more flexibility the potential of UHF for brain imaging.

SUBMITTER: Gras V 

PROVIDER: S-EPMC5565195 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Homogeneous non-selective and slice-selective parallel-transmit excitations at 7 Tesla with universal pulses: A validation study on two commercial RF coils.

Gras Vincent V   Boland Markus M   Vignaud Alexandre A   Ferrand Guillaume G   Amadon Alexis A   Mauconduit Franck F   Le Bihan Denis D   Stöcker Tony T   Boulant Nicolas N  

PloS one 20170821 8


Parallel transmission (pTx) technology, despite its great potential to mitigate the transmit field inhomogeneity problem in magnetic resonance imaging at ultra-high field (UHF), suffers from a cumbersome calibration procedure, thereby making the approach problematic for routine use. The purpose of this work is to demonstrate on two different 7T systems respectively equipped with 8-transmit-channel RF coils from two different suppliers (Rapid-Biomed and Nova Medical), the benefit of so-called uni  ...[more]

Similar Datasets

| S-EPMC6372346 | biostudies-literature
| S-EPMC4909507 | biostudies-literature
| S-EPMC5574011 | biostudies-literature
| S-EPMC5453143 | biostudies-other
| S-EPMC7180091 | biostudies-literature
| S-EPMC4090294 | biostudies-literature
| S-EPMC6289759 | biostudies-literature
| S-EPMC4151532 | biostudies-literature
| S-EPMC2798032 | biostudies-other
| S-EPMC4654723 | biostudies-literature