Unknown

Dataset Information

0

Standing Surface Acoustic Wave (SSAW)-Based Fluorescence-Activated Cell Sorter.


ABSTRACT: Microfluidic fluorescence-activated cell sorters (?FACS) have attracted considerable interest because of their ability to identify and separate cells in inexpensive and biosafe ways. Here a high-performance ?FACS is presented by integrating a standing surface acoustic wave (SSAW)-based, 3D cell-focusing unit, an in-plane fluorescent detection unit, and an SSAW-based cell-deflection unit on a single chip. Without using sheath flow or precise flow rate control, the SSAW-based cell-focusing technique can focus cells into a single file at a designated position. The tight focusing of cells enables an in-plane-integrated optical detection system to accurately distinguish individual cells of interest. In the acoustic-based cell-deflection unit, a focused interdigital transducer design is utilized to deflect cells from the focused stream within a minimized area, resulting in a high-throughput sorting ability. Each unit is experimentally characterized, respectively, and the integrated SSAW-based FACS is used to sort mammalian cells (HeLa) at different throughputs. A sorting purity of greater than 90% is achieved at a throughput of 2500 events s-1 . The SSAW-based FACS is efficient, fast, biosafe, biocompatible and has a small footprint, making it a competitive alternative to more expensive, bulkier traditional FACS.

SUBMITTER: Ren L 

PROVIDER: S-EPMC6291339 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Standing Surface Acoustic Wave (SSAW)-Based Fluorescence-Activated Cell Sorter.

Ren Liqiang L   Yang Shujie S   Zhang Peiran P   Qu Zhiguo Z   Mao Zhangming Z   Huang Po-Hsun PH   Chen Yuchao Y   Wu Mengxi M   Wang Lin L   Li Peng P   Huang Tony Jun TJ  

Small (Weinheim an der Bergstrasse, Germany) 20180831 40


Microfluidic fluorescence-activated cell sorters (μFACS) have attracted considerable interest because of their ability to identify and separate cells in inexpensive and biosafe ways. Here a high-performance μFACS is presented by integrating a standing surface acoustic wave (SSAW)-based, 3D cell-focusing unit, an in-plane fluorescent detection unit, and an SSAW-based cell-deflection unit on a single chip. Without using sheath flow or precise flow rate control, the SSAW-based cell-focusing techniq  ...[more]

Similar Datasets

| S-EPMC4442640 | biostudies-literature
| S-EPMC3956078 | biostudies-literature
| S-EPMC4188268 | biostudies-literature
| S-EPMC4688895 | biostudies-literature
| S-EPMC3988909 | biostudies-literature
| S-EPMC4888785 | biostudies-literature
| S-EPMC3997299 | biostudies-literature
| S-EPMC4856433 | biostudies-literature
| S-EPMC3965373 | biostudies-literature
| S-EPMC8267599 | biostudies-literature