Unknown

Dataset Information

0

An automated high throughput solution for DNA extraction and bisulfite-conversion from high volume liquid biopsy specimens: sample preparation for epigenetic analysis.


ABSTRACT: OBJECTIVE:DNA methylation analysis via real-time PCR or other analytical techniques requires purified bisulfite converted DNA. We report on an automated high throughput solution for DNA extraction, bisulfite-conversion, and purification of 96 samples with an input volume of up to 3.5 mL of plasma or urine, using reagents from the commercially available Epi BisKit. RESULTS:Magnetic bead-based DNA extraction, bisulfite conversion at high temperature, and efficient DNA purification was conducted on a customized commercially available liquid-handling platform. A highly interlaced 4?×?24 sample protocol was implemented for DNA extraction, elution in a 96-well plate, efficient bisulfite-conversion and extensive purification. The resulting bisulfite-converted DNA was stored in a 96-well format, ready for PCR set-up or other down-stream applications. The automated method is a walk-away solution for processing 96 samples in 7 h 30 min. Performance of the method was validated by comparison with the standard manual method of the Epi BiSKit using technical and biological samples. Overall DNA yield was assessed with a standardized ?-actin assay. The automated workflow demonstrated equivalent performance to the manual method for technical, plasma and urine samples. It may provide a new standard for effective high-throughput preparation of bisulfite-converted DNA from a variety of high volume liquid biopsy specimens.

SUBMITTER: Rausch S 

PROVIDER: S-EPMC6716871 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

An automated high throughput solution for DNA extraction and bisulfite-conversion from high volume liquid biopsy specimens: sample preparation for epigenetic analysis.

Rausch Sebastian S   Hasinger Oliver O   König Thomas T   Schlegel Anne A   Weiss Gunter G  

BMC research notes 20190830 1


<h4>Objective</h4>DNA methylation analysis via real-time PCR or other analytical techniques requires purified bisulfite converted DNA. We report on an automated high throughput solution for DNA extraction, bisulfite-conversion, and purification of 96 samples with an input volume of up to 3.5 mL of plasma or urine, using reagents from the commercially available Epi BisKit.<h4>Results</h4>Magnetic bead-based DNA extraction, bisulfite conversion at high temperature, and efficient DNA purification w  ...[more]

Similar Datasets

| S-EPMC5710880 | biostudies-other
| S-EPMC3751724 | biostudies-literature
| S-EPMC2259111 | biostudies-literature
| S-EPMC5735811 | biostudies-other
| S-EPMC5778454 | biostudies-literature
| S-EPMC8777774 | biostudies-literature
| S-EPMC7105554 | biostudies-literature
| S-EPMC3500568 | biostudies-literature
| S-EPMC5290157 | biostudies-literature
| S-EPMC5383381 | biostudies-literature